- Name:
- INTELLIGENT CIRCULATION PUMP
- Model:
- INTELLIGENT CIRCULATION PUMP
- Categories:
- INTELLIGENT CIRCULATION PUMP
- View:
- 7067
- Comments:
- INTELLIGENT CIRCULATION PUMP
- Contact:
- Contact Us
Detailed Info

Energy Saving Circulation Pumps | |||||||
Power | Head | Flow | Length | Inlet/Outlet | N.M | ||
AUTOCR25-6 | Max | 45W | 6M | 3.4M³/H | 180mm | 1 1/2 inch | 1.9KGS |
Min | 5W | 0 | 0 | ||||
AUTOCR25-4 | Max | 22W | 4M | 2.5M³/H | 180mm | 1 1/2 inch | 1.9KGS |
Min | 5W | 0 | 0 |
Control board running performance | |||||||
Runnning state | When in Maximum flow | When Flow=0 | Remark | ||||
Power (W) |
Flowrate (M3/H) |
Pressure (bar) |
Power (W) |
Flowrate (M3/H) |
Max.head (M) |
||
1 | 20 | 1.3 | 0.0065 | 5 | 0 | 1.3 | can display night mode |
2 | 43 | 1.6 | 0.015 | 9 | 0 | 2.5 | |
3 | 44 | 2.5 | 0.015 | 16 | 0 | 4 | |
4 | 45 | 3.0 | 0.015 | 26 | 0 | 5 | |
Ⅰ | 7 | 1.8 | 0.003 | 5 | 0 | 1.3 | Constant speed |
Ⅱ | 28 | 2.5 | 0.011 | 16 | 0 | 4 | |
Ⅲ | 45 | 3.1 | 0.016 | 40 | 0 | 6 | |
auto | 43 | 3.0 | 0.013 | 5W | 0 | 1.3 | |
Auto Nighttime | 5 |
REMARK:
1.Mode1,2,3,4is control mode of proportional pressure;Mode Ⅰ,Ⅱ,Ⅲis control mode of constant speed.Auto mode is control mode of proportional pressure+temperature.
2.Run mode of Auto:in each flow period,power P is a range of values,the maximum power of W value corresponding to the minimum temperature,the temperature range of 30-95.
3.Electric mode:no switches,power according to the last time which mode the system running before it been powered off.
4.Display order:AUTO-1-2-3-4-Ⅲ-Ⅱ-Ⅰ.In the AUTO-1-2-3-4 model can display the night mode.